{"product_id":"mayser-sg-efs-104-zk2-1-sicherheitsschaltgerat-24v-ac-dc-gebraucht-kopie-1","title":"Bircher Reglomat ESD3-6171 safety relay","description":"\u003cp\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cstrong data-redactor-tag=\"strong\"\u003e\u003cspan rel=\"font-size: 24px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 24px;\"\u003eBircher Reglomat ESD3-6171 safety relay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003eTechnical details:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Manufacturer: Bircher Reglomat AG\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Model: ESD3-6171\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Type: Safety relay\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Category: Cat.3 (EN 954-1)\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Response time: max. 50ms\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Operating voltage: 24V AC\/DC ±10% 50Hz\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Load current: 2A \/ 250VAC\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Q-CH-NR: 0708020011\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Version: V8\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Weight: approx. 150g\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Dimensions: 22.5 x 99 x 114.5 mm\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003eAreas of application:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• The Bircher Reglomat ESD3-6171 safety relay is used in safety circuits of machines and systems to ensure safe shutdown in the event of danger. It is used in industrial automation and in safety systems for machines.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003eSpecial features:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• High safety according to category 3 (EN 954-1)\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Fast response time of max. 50ms\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Reliable function with an operating voltage of 24V AC\/DC\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003e• Robust design for use in industrial environments\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan rel=\"font-size: 20px;\" data-verified=\"redactor\" data-redactor-tag=\"span\" data-redactor-style=\"font-size: 20px;\"\u003eUsed device removed from a running system.\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003eOperating voltage:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• 24 V AC ±10%, 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• 24VDC ±10%\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• 115V AC ±10%, 60Hz\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• 230 V AC ±10%, 50 Hz\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Power consumption: Max. 5 VA\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Safety outputs:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Use category according to EN 60947-4-1:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• AC-1: 230 V\/2 A\/460 VA, approx. 280,000 switching cycles\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• DC-1: 24 V\/2 A\/48 W, approx. 500,000 switching cycles\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Usage category according to EN 60947-5-1:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• AC-15: 230 V\/2 A\/460 VA, approx. 150,000 switching cycles\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• DC-13: 24 V\/2 A\/48 W, approx. 80,000 switching cycles\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Contact protection: Internal 2 A slow\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Service life: Mechanical 10 million switching cycles\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Response time: \u0026lt; 50 ms\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003eStatus relay:\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Switching capacity:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• 24 V DC \/ 1 A, resistive load\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• 30V AC \/ 1A, resistive load\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003eEnvironmental conditions:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Protection class: IP20 (EsGate, ESD3), IP30 (ESR3)\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Operating temperature:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• EsGate: -20 °C to +60 °C\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• ESD3: -20 °C to +55 °C\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• ESR3: -20 °C to +50 °C\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Storage temperature:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• EsGate: -40 °C to +70 °C\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• ESD3, ESR3: -20 °C to +80 °C\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Humidity:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• EsGate: Max. 95% relative, non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• ESD3, ESR3: Max. 80% relative, non-condensing\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003eAreas of application\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003eThe ESD3-6171 safety relay is used in various safety-critical applications including:\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Machine protection: Protection of danger zones on machines.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Gate controls: Securing gates and doors in industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Safety circuits: Integration into safety circuits for machine control.\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003eSpecial features\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• High safety according to category 3 (EN 954-1)\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Fast response time of max. 50ms\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Reliable function with an operating voltage of 24V AC\/DC\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Robust design for use in industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Forced relays and redundant signal evaluation\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003e• Mounting on DIN rail\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003eFor downloads and further information, see Downloads or \u003ca href=\"https:\/\/smartaccess.bircher.com\/de\/\"\u003ehttps:\/\/smartaccess.bircher.com\/de\/\u003c\/a\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003eGoods tariff number\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan data-redactor-tag=\"span\" data-verified=\"redactor\" data-redactor-style=\"font-size: 20px;\"\u003eThe corresponding HS Code (commodity tariff number) for safety relays is: 8536.49\u003c\/span\u003e\u003c\/p\u003e\n\n\u003c!----\u003e","brand":"MAYSER","offers":[{"title":"Default Title","offer_id":52948762755411,"sku":"300- 0708020011","price":44.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0823\/6964\/2835\/files\/IMG_2216-MAYSERSG-EFS104ZK2_1SicMAYSERSG-EFS104ZK2_1Sichherheitsschaltgeraet100084_98f0a00e-da8c-459a-96ac-04e312c717ae.jpg?v=1740173259","url":"https:\/\/sondermann.org\/en\/products\/mayser-sg-efs-104-zk2-1-sicherheitsschaltgerat-24v-ac-dc-gebraucht-kopie-1","provider":"Gerhard Sondermann GmbH","version":"1.0","type":"link"}